Mirrored scale for easy and accurate reading. |
| • |
Fuse and diode protected circuit (except 15A AC range). |
| • |
Output terminal to cut off DC component when measuring AC voltage. |
| • |
Safety designed input terminals and test leads. | 
 |
Do not make voltage measurements on industry power lines of 250V or higher. | |
|
|
| DC V |
0.5/5/25/100/250/500V(5kΩ/V) |±3% of FS |
| AC V |
10/50/250/500V(2.5kΩ/V) |±3% of FS |
| DC A |
200µA/2.5/25/250mA |±3% of FS |±5% of FS(250mA) |
| Ω |
3/30/300kΩ |±3% of scale length |
| Temperature |
-20ºC~+150ºC |±5ºC(0ºC~+100ºC) |±10ºC(other ranges) (with the use of Temperature probe 7060) |
| Battery Test |
2V(20Ω load) |
| Withstand Voltage |
3000V AC for 1 minute |
| Power Source |
R6P(AA)(1.5V) × 1 |
| Dimensions |
130(L) × 85(W) × 38(D)mm |
| Weight |
175g approx. |
| Accessories |
7066(Test Leads) 8901(0.5A/250V fuse) × 1 R6P(AA) × 1 Instruction Manual 9059(Carrying Case)
|
| Optional |
7060(Temperature Probe) | | |
| |
|
|
|
|
|
|
|
|
|