High sensitivity DC20kΩ/V. |
| • |
Polarity selector switch. |
| • |
1m drop-proof heavy duty designed taut-band movement. |
| • |
Can measure line voltage up to AC 600V. (Voltage to ground MAX AC300V) (Protected by 600V ceramic fuse against accidental overload) |
| • |
Continuity buzzer, battery check, LED check, temperature measurement function. |
| • |
Skeleton type robust and clear case with carrying handle furnished as standard accessory. |  |
|
|
| DC V |
0.3V(16.7kΩ/V) ±3% of FS 3/12/30/120/300/600V(20kΩ/V) |±3% of FS |
| AC V |
12V(9kΩ/V) ±4% of FS 30/120/300/600V(9kΩ/V) |±3% of FS |
| DC A |
60µA/30/300mA |±3% of FS |
| Ω |
3/30/300kΩ |±3% of scale length |
| Continuity buzzer |
Buzzer sounds below 100Ω |
| LED |
10mA approx. at 0 Ω (at 3V of battery voltage) |
| Temperature |
-20ºC~+150ºC |±3% of scale length (0ºC~+100ºC) |±4% of scale length (other ranges) (with the use of Temperature probe 7060) |
| Battery Test |
1.5V(0.7~2V) |±3% of FS (10Ω load) |
Maximum Circuit Voltage |
600V AC/DC (between line/neutral) 300V AC/DC (against earth) |
| Safety Standard |
| IEC61010-1 |
 |
CAT.III 300V Pollution Degree 2 |
|
|
CAT.II 600V Pollution Degree 2 | IEC61010-2-031 |
| Withstand Voltage |
3700V AC for 1 minute |
| Power Source |
R6P(AA)(1.5V) × 2 |
| Dimensions |
94(L) × 140(W) × 39(D)mm |
| Weight |
280g approx. |
| Accessories |
7066(Test Leads) 8923(F500mA/600V fuse) × 2 R6P(AA) × 2 9103(Carrying Case) Instruction Manual |
| Optional |
7060(Temperature Probe) | | | | |
|
|
|
|
|
|
|
|
|