Language:
Currency:
VAT Mode:
Now In:
→ KEW 2002PA 750V 400A Digital Clamp Meter
|
|
| • |
Can measure large AC current up to 2000A. |
| • |
Peak hold function. |
| • |
55mm-dia large tear drop shaped jaws. |
|
|
| AC A |
400A (0~400A) |±1%rdg±3dgt [50/60Hz] |±2%rdg±3dgt [40Hz~1kHz] 2000A (0~1500A) |±1%rdg±3dgt [50/60Hz] |±3%rdg±3dgt [40Hz~1kHz] 2000A (1500~2000A) |±3.0%rdg [50/60Hz] |
| AC V |
40/400/750V |±1%rdg±2dgt [50/60Hz] |±1.5%rdg±3dgt [40Hz~1kHz] |
| DC V |
40/400/1000V ±1%rdg±2dgt |
| Ω |
400Ω/4k/40k/400kΩ|±1.5%rdg±2dgt |
| Continuity buzzer |
buzzer sounds below 50±35Ω |
| Output Voltage |
400/2000A DC400mV/200mV |
| Conductor Size |
Ø55mm max. |
| Safety Standard |
| IEC61010-1 |
 |
CAT.III 600V |
|
|
CAT.II 1000V | IEC61010-2-031 IEC61010-2-032 |
| Frequency Response |
40Hz~1kHz |
| Withstand Voltage |
5550V AC for 1 minute |
| Power Source |
R6P(AA)(1.5V) × 2 |
| Dimensions |
247(L) × 105(W) × 49(D)mm |
| Weight |
470g approx. |
| Accessories |
7107(Test Leads) 8201(Output Plug) 9094(Carrying Case) R6P(AA) × 2 Instruction Manual |
| Optional |
8004/8008(Multi-Tran) 7014(Output Cord) | | | |
|
| |
|
|
|
|
|
|
|
|
|